Liquid Analysis

Comprehensive product range for all analytical parameters.

1 - 48 of 188 Products
Memobase CYZ71D
Endress+Hauser
Memobase CYZ71D
Request a Quote
Multi parameter measuring device Hand held CML18
Endress+Hauser
Multi parameter measuring device Hand held CML18
Lean Lean
Request a Quote
Flowfit CYA21
Endress+Hauser
Flowfit CYA21
Request a Quote
Liquiline, 4-wire CM444
Endress+Hauser
Liquiline, 4-wire CM444
Extended Extended
Request a Quote
Digital measuring cable Measuring cable CYK10
Endress+Hauser
Digital measuring cable Measuring cable CYK10
Request a Quote
Liquiline, 4-wire CM448
Endress+Hauser
Liquiline, 4-wire CM448
Extended Extended
Request a Quote
Memosens CLS82E
Endress+Hauser
Memosens CLS82E
Extended Extended
Request a Quote
Liquiline, 4-wire CM444R
Endress+Hauser
Liquiline, 4-wire CM444R
Extended Extended
Request a Quote
CLY421
Endress+Hauser
CLY421
Request a Quote
Conductivity sensor Indumax CLS50
Endress+Hauser
Conductivity sensor Indumax CLS50
Request a Quote
Ceragel CPS71
Endress+Hauser
Ceragel CPS71
Request a Quote
Liquiline, 4-wire CM44P
Endress+Hauser
Liquiline, 4-wire CM44P
Extended Extended
Request a Quote
Memosens CPS71E
Endress+Hauser
Memosens CPS71E
Extended Extended
Request a Quote
Digital pH sensor Orbisint CPS11D
Endress+Hauser
Digital pH sensor Orbisint CPS11D
Extended Extended
Request a Quote
Flexdip CYA112
Endress+Hauser
Flexdip CYA112
Request a Quote
Cleanfit CPA875
Endress+Hauser
Cleanfit CPA875
Request a Quote
Oxymax COS61
Endress+Hauser
Oxymax COS61
Request a Quote
Digital pH sensor Memosens Wave CPL51E
Endress+Hauser
Digital pH sensor Memosens Wave CPL51E
Fundamental Fundamental
Request a Quote
Memosens CPS42E
Endress+Hauser
Memosens CPS42E
Request a Quote
Viomax CAS51D
Endress+Hauser
Viomax CAS51D
Extended Extended
Request a Quote
Conductivity sensor Memosens CLL47E
Endress+Hauser
Conductivity sensor Memosens CLL47E
Request a Quote
Memosens CLS21E
Endress+Hauser
Memosens CLS21E
Extended Extended
Request a Quote
Memosens CCS51E
Endress+Hauser
Memosens CCS51E
Extended Extended
Request a Quote
Hand held CYM290
Endress+Hauser
Hand held CYM290
Request a Quote
Chemoclean CYR10B
Endress+Hauser
Chemoclean CYR10B
Request a Quote
Memosens CPS16E
Endress+Hauser
Memosens CPS16E
Extended Extended
Request a Quote
Zero point gel Miscellaneous COY8
Endress+Hauser
Zero point gel Miscellaneous COY8
Request a Quote
Oxymax COS41
Endress+Hauser
Oxymax COS41
Request a Quote
pH sensor Memosens CPL57E
Endress+Hauser
pH sensor Memosens CPL57E
Request a Quote
Transmitter Liquiline, 2-wire CM42
Endress+Hauser
Transmitter Liquiline, 2-wire CM42
Extended Extended
Request a Quote
Sensor CCS50
Endress+Hauser
Sensor CCS50
Request a Quote
Oxygen sensor Memosens COL37E
Endress+Hauser
Oxygen sensor Memosens COL37E
Request a Quote
In-line Photometer OUSAF44
Endress+Hauser
In-line Photometer OUSAF44
Extended Extended
Request a Quote
Transmitter Liquiline, 4-wire CM442
Endress+Hauser
Transmitter Liquiline, 4-wire CM442
Extended Extended
Request a Quote
In-line Photometer OUSAF22
Endress+Hauser
In-line Photometer OUSAF22
Extended Extended
Request a Quote
Digital measuring cable Memobase CYK20
Endress+Hauser
Digital measuring cable Memobase CYK20
Request a Quote
Flexdip CYH112
Endress+Hauser
Flexdip CYH112
Request a Quote
In-line Photometer OUSBT66
Endress+Hauser
In-line Photometer OUSBT66
Extended Extended
Request a Quote
Orbipore CPS92D
Endress+Hauser
Orbipore CPS92D
Request a Quote
Liquiline, 4-wire CYY7
Endress+Hauser
Liquiline, 4-wire CYY7
Extended Extended
Request a Quote
Liquiline, 4-wire CM442R
Endress+Hauser
Liquiline, 4-wire CM442R
Extended Extended
Request a Quote
Indumax CLS54D
Endress+Hauser
Indumax CLS54D
Extended Extended
Request a Quote
Condumax CLS12
Endress+Hauser
Condumax CLS12
Request a Quote
Liquiline System CA76NA
Endress+Hauser
Liquiline System CA76NA
Request a Quote
Transmitter Liquiline, 2-wire CM72
Endress+Hauser
Transmitter Liquiline, 2-wire CM72
Request a Quote
Redox sensor Memosens CPS12E
Endress+Hauser
Redox sensor Memosens CPS12E
Extended Extended
Request a Quote
Condumax CLS15
Endress+Hauser
Condumax CLS15
Request a Quote
Memocheck CYP02E
Endress+Hauser
Memocheck CYP02E
Request a Quote

Liquid Analysis

Liquid analysis covers the measurement of analytical parameters that define chemistry and quality in aqueous and process liquids. These measurements underpin environmental protection, consistent product quality, process optimization, and safety, particularly where control decisions depend on chemical state rather than only physical variables. Endress+Hauser positions liquid analysis as a comprehensive product range across parameters and application types, from utilities to in-process measurements.

The Endress+Hauser liquid analysis offering includes pH and ORP sensors/transmitters, conductivity, turbidity, disinfection/chlorine, oxygen, laboratory and portable instruments, automatic water samplers, TOC/COD/SAC analyzers, sludge level sensors, nutrient analyzers, analyzers for hardness/iron and other constituents, process photometers, and microwave transmission measurement. This breadth supports architectures ranging from single-parameter loops to multi-parameter stations with shared transmitter platforms.

A key operational advantage in modern analytical loops is signal integrity and maintainability. Endress+Hauser highlights Memosens as a digital approach that converts the measured value to a digital signal and transfers it to the transmitter without a contacting connection, supporting more resilient measurement and maintenance workflows in demanding environments. In addition, the portfolio emphasizes integration into communication interfaces and plant asset management, and end-to-end lifecycle support.

Typical applications include drinking-water treatment and distribution, wastewater aeration control and nutrient removal, neutralization and effluent compliance monitoring, boiler and cooling-water chemistry, beverage and dairy quality control, and chemical and pharmaceutical process monitoring. Samplers and analyzers support regulatory reporting and troubleshooting, while inline sensors support closed-loop control, alarm management, and process optimization with faster feedback than lab-only approaches.

Engineering considerations include sample representativeness (inline vs. bypass), sensor mounting (fixed or retractable assemblies), cleaning and calibration routines, temperature compensation, and drift detection. Analyzer selection should match the required detection limits, interferences, and response time, with communication and documentation practices aligned to auditability needs. Reliability is typically maximized when sensor handling, spare strategy, and verification intervals are defined alongside the control philosophy rather than after startup.

Instrumentation and Controls., an exclusive authorized representative of sales and service for Endress+Hauser.