pH Sensors & Transmitters

Products for high-quality pH measurement in all industries.

1 - 48 of 80 Products
Multiparameter Handheld Liquiline Mobile CML18
Endress+Hauser
Liquiline Mobile CML18_s_stehend_001.png
Lean Lean
Request Information
Digital pH Sensor Memosens CPL51E
Endress+Hauser
CPL51E_s_20.01._001.png
Fundamental Fundamental
Request Information
Analog pH Sensor Orbipore CPS91
Endress+Hauser
cps91 spitze.png
Request Information
Multichannel Multiparameter Software Memobase Plus CYZ71D
Endress+Hauser
CYZ71D.png
Request Information
Combined pH/ORP Sensor Memosens CPS76E
Endress+Hauser
CPS76E-combined-pH-ORP-sensor.png
Extended Extended
Request Information
Digital pH Sensor Orbisint CPS11D
Endress+Hauser
CPS11D_Ex_front.png
Extended Extended
Request Information
Digital pH Sensor Memosens CPS71E
Endress+Hauser
CPS71E-pH-sensor.png
Extended Extended
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA474
Endress+Hauser
CPA474.png
Request Information
Digital Non-Glass pH Sensor Ceramax CPS341D
Endress+Hauser
cps341d_ceramax gerade.png
Extended Extended
Request Information
Ex-Certified Multiparameter Handheld Liquiline To Go CYM291
Endress+Hauser
LiquilineTo Go CYM291.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA875
Endress+Hauser
CPA875_pneumatic_measuring_position.png
Request Information
Digital pH Sensor Memosens CPS11E
Endress+Hauser
CPS11E-pH-sensor-ion-trap-ex-version-straight.png
Extended Extended
Request Information
Analog pH Sensor Ceraliquid CPS41
Endress+Hauser
cps41 - mit TOP68.png
Request Information
Digital pH Sensor Memosens CPL59E
Endress+Hauser
Memosens CPL59E.png
Request Information
Digital Service Tool Memocheck CYP02E
Endress+Hauser
Digital service tool Memocheck CYP02E
Request Information
Process Assembly Ecofit CPA640
Endress+Hauser
CPA640.png
Request Information
pH Buffer CPY20
Endress+Hauser
CPY20 pH buffers.png
Request Information
Cleaning Unit Cleanfit Control CYC25
Endress+Hauser
Cleaning unit Cleanfit Control CYC25
Request Information
Liquiline Edge Module CYY7
Endress+Hauser
Liquiline Edge Module CYY7
Extended Extended
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
Analog pH Sensor Ceragel CPS71
Endress+Hauser
cps71-pH-sensor-front.png
Request Information
1-Channel Transmitter Liquiline Compact CM82
Endress+Hauser
Liquiline Compact CM82_angular.png
Request Information
Analog pH Sensor Ceratex CPS31
Endress+Hauser
CPS31_pH_sensor_angular.png
Request Information
Manual or Automatic Retractable Assembly Cleanfit CPA871
Endress+Hauser
cpa871_peek_immersion_chamber_manual.png
Request Information
Digital pH Sensor Memosens CPS31E
Endress+Hauser
CPS31E-pH-sensor-salt-storage.png
Extended Extended
Request Information
Flow Assembly Flowfit CYA21
Endress+Hauser
CYA21_Durchflussarmatur 71042404_g_001.png
Request Information
4-Channel Transmitter Liquiline CM444
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Digital pH Sensor Memosens CPS171D
Endress+Hauser
CPS171D_front.png
Extended Extended
Request Information
Digital pH Sensor Memosens CPF81E
Endress+Hauser
CPF81E-digital-pH-sensor.png
Extended Extended
Request Information
1-/2-Channel Transmitter Liquiline CM442R
Endress+Hauser
CM442R.png
Extended Extended
Request Information
1-Channel Transmitter Liquiline M CM42
Endress+Hauser
CM42_plastic version_angular.png
Extended Extended
Request Information
4-Channel Transmitter Liquiline CM444R
Endress+Hauser
CM444R.png
Extended Extended
Request Information
Manual Retractable Assembly Cleanfit CPA450
Endress+Hauser
CPA450.png
Request Information
Immersion Assembly Dipfit CPA111
Endress+Hauser
CPA111_front.png
Request Information
1-/2-Channel Transmitter Liquiline CM442
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Digital pH Sensor Ceraliquid CPS41D
Endress+Hauser
cps41d - Ex - cmyk.png
Request Information
Analog pH Sensor Purisys CPF201
Endress+Hauser
cpf201-purisys 03.png
Request Information
Flow Assembly Flowfit CPA25
Endress+Hauser
Flow assembly Flowfit CPA25
Lean Lean
Request Information
Digital Extension Cable Memosens CYK11
Endress+Hauser
Digital extension cable CYK11
Request Information
Digital pH Sensor Memosens CPS61E
Endress+Hauser
CPS61E-digital-ph-sensor.png
Extended Extended
Request Information
pH/ORP Transmitter Liquisys CPM223
Endress+Hauser
CPM223.png
Request Information
Immersion Assembly Flexdip CYA112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
Cleaning Injector Chemoclean CYR10B
Endress+Hauser
Cleaning injector Chemoclean CYR10B
Request Information
Digital pH Sensor Memosens CPL57E
Endress+Hauser
Memosens CPL57E.png
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Memosens Analog Converter CYM17
Endress+Hauser
Converterbox CYM17_s_001.png
Request Information
Immersion Assembly Dipfit CPA140
Endress+Hauser
CPA140_front.png
Request Information
Digital Combined pH/ORP Sensor Memosens CPS96E
Endress+Hauser
CPS96E-combined-pH-ORP-sensor-Beauty.png
Extended Extended
Request Information

pH Sensors & Transmitters

pH measurement systems provide continuous indication of acidity/alkalinity in liquids, using a pH sensor and transmitter to deliver a compensated, diagnostic-rich process signal. The measurement is fundamental to reaction control, corrosion management, biological treatment performance, and product quality across a wide range of industries. Because pH influences speciation, solubility, and reaction rates, it is often a primary control variable rather than a secondary indicator.

The benefit is direct control of critical chemistry with immediate feedback. Accurate pH monitoring supports optimized neutralization, improved precipitation and coagulation performance, reduced chemical overfeed, and protection of downstream assets. Continuous pH data also strengthens compliance assurance in discharge applications where permit limits require reliable documentation.

Sensor technology includes glass electrodes for general use, specialized glass formulations for high temperature or low conductivity, and alternative designs (such as ISFET-based sensors) for rapid response or difficult media. Reference junction design and electrolyte management strongly influence stability in dirty, sulfide-bearing, or high-solids services. Installation assemblies may include retractable housings, cleaning chambers, and automatic rinsing to maintain performance in fouling environments.

Transmitters add temperature compensation, filtering, alarm handling, and sensor diagnostics such as impedance monitoring and slope tracking. Diagnostics help detect glass aging, reference poisoning, and coating before measurement quality degrades to the point of control instability. Calibration strategy - buffer selection, frequency, and documentation - should be aligned to process criticality and exposure to fouling or chemical shock.

Typical applications include acid/caustic dosing, wastewater neutralization and compliance monitoring, chemical reaction control, cooling water and boiler utility conditioning, and hygienic processes such as CIP. pH is also central in biological treatment, where it affects nitrification, toxicity, and metal solubility. With correct sensor selection, installation, and maintenance planning, pH measurement remains one of the most powerful and cost-effective analytical tools in process control.

Instrumentation and Controls., an exclusive authorized representative of sales and service for Endress+Hauser.