Chlorine Sensors & Transmitters

Products for reliable measurement of chlorine and bromine-based disinfectants.

1 - 25 of 25 Products
Digital Total Chlorine Sensor Memosens CCS53E
Endress+Hauser
Digital total chlorine sensor Memosens CCS53E
Extended Extended
Request Information
Analog Free Chlorine Sensor Memosens CCS51
Endress+Hauser
Analog free chlorine sensor CCS51
Request Information
Zero-Point Gel COY8
Endress+Hauser
Zero_point_gel_COY8_1.png
Request Information
Digital Service Tool Memocheck CYP02E
Endress+Hauser
Digital service tool Memocheck CYP02E
Request Information
Digital Chlorine Dioxide Sensor Memosens CCS50E
Endress+Hauser
Digital chlorine dioxide sensor Memosens CCS50E
Extended Extended
Request Information
Liquiline Edge Module CYY7
Endress+Hauser
Liquiline Edge Module CYY7
Extended Extended
Request Information
Flow Assembly for Multi-Parameter Measurements Flowfit CYA27
Endress+Hauser
Flow assembly for multi-parameter measurements Flowfit CYA27
Request Information
4-Channel Transmitter Liquiline CM444
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
1-/2-Channel Transmitter Liquiline CM442R
Endress+Hauser
CM442R.png
Extended Extended
Request Information
4-Channel Transmitter Liquiline CM444R
Endress+Hauser
CM444R.png
Extended Extended
Request Information
1-/2-Channel Transmitter Liquiline CM442
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
Digital Extension Cable Memosens CYK11
Endress+Hauser
Digital extension cable CYK11
Request Information
Immersion Assembly Flexdip CYA112
Endress+Hauser
CYA112_Rendering_2.png
Request Information
Analog Chlorine Dioxide Sensor Memosens CCS50
Endress+Hauser
Analog chlorine dioxide sensor CCS50
Request Information
Multichannel Transmitter Liquiline CM44P
Endress+Hauser
Liquiline_CM44P_AU.png
Extended Extended
Request Information
Disinfection Transmitter Liquisys CCM223
Endress+Hauser
Disinfection transmitter Liquisys CCM223
Request Information
Digital Ozone Sensor Memosens CCS58E
Endress+Hauser
Digital ozone sensor Memosens CCS58E
Extended Extended
Request Information
Digital Service and Qualification Tool Memocheck Sim CYP03D
Endress+Hauser
Digital service and qualification tool Memocheck Sim CYP03D
Request Information
Digital Measuring Cable Memosens CYK10
Endress+Hauser
Digital measuring cable CYK10
Request Information
8-Channel Transmitter Liquiline CM448
Endress+Hauser
CM44_pH.png
Extended Extended
Request Information
8-Channel Transmitter Liquiline CM448R
Endress+Hauser
CM448R.png
Extended Extended
Request Information
Digital Measuring Cable CYK20
Endress+Hauser
CYK20_Memosens cable_nonEx.png
Request Information
Disinfection Transmitter Liquisys CCM253
Endress+Hauser
Disinfection transmitter Liquisys CCM253
Request Information
Digital Free Chlorine Sensor Memosens CCS51E
Endress+Hauser
Digital free chlorine sensor Memosens CCS51E
Extended Extended
Request Information
Digital Free Bromine Sensor Memosens CCS55E
Endress+Hauser
Digital free bromine sensor Memosens CCS55E
Extended Extended
Request Information

Chlorine Sensors & Transmitters

Chlorine measurement systems provide continuous monitoring of disinfectant residuals in water and aqueous process streams. The category typically covers free chlorine, total chlorine (free plus combined), and related oxidants where selective measurement is required. A sensor paired with a transmitter converts electrochemical reaction signals into stable, temperature-compensated process values for control and compliance.

The key benefit is consistent disinfection performance with minimized chemical overfeed. Stable residual control supports pathogen inactivation targets while reducing taste/odor issues, byproduct formation, and chemical cost. Continuous monitoring also provides rapid detection of residual loss due to process upsets, high demand events, or dosing system faults.

Common measurement principles include amperometric sensors with membrane-covered electrodes and defined electrolyte systems, designed for fast response and robust selectivity. Depending on the residual type, measurement may incorporate pH compensation or be paired with a pH signal to correct for hypochlorous acid/hypochlorite equilibrium. Proper flow conditions - often provided by a flow assembly - improve repeatability and help protect the sensor from air entrainment and debris.

Transmitters provide scaling, filtering, diagnostics, and communications for integration into control architectures. Advanced diagnostics (sensor impedance, polarization status, slope monitoring) help distinguish true residual changes from sensor drift or fouling. Cleaning strategies range from manual wipe-down to automated flushing, with maintenance intervals driven largely by water quality, solids loading, and biofouling tendency.

Typical applications include drinking water treatment and distribution, disinfection contact basins, wastewater disinfection, industrial cooling water, and sanitization processes in food and beverage utilities. Residual monitoring is also used to verify dechlorination performance before discharge and to protect downstream biological treatment stages. With correct installation and verification practices, chlorine measurement becomes a dependable lever for both safety and cost control.

Instrumentation and Controls., an exclusive authorized representative of sales and service for Endress+Hauser.